Heil makes straightforward ducted heating and cooling equipment built from standard parts. On a Heil, the equipment is often not the hard part of the repair; the ducts, the coil match and the airflow around it often are.

  • 24/7 emergency service
  • Same-day service available
  • Free installation estimates

Heil heating and air equipment in Menlo Park, Atherton and Portola Valley is ducted: a gas furnace or air handler indoors with an air conditioner or heat pump outside, or a packaged unit that holds the whole system in one outdoor cabinet. Most of what fails on it is standard: capacitors, contactors, igniters, flame sensors, motors. Those parts are easy to identify and quick to replace. The harder question is whether the system around the equipment works: the ducts, the indoor coil and the airflow.

What Heil makes

Gas furnaces, central air conditioners, heat pumps, air handlers, indoor coils and packaged units. Most of the range is single-stage or two-stage equipment wired to a conventional thermostat. Its lines include Ion at the top, with variable-speed equipment that can run as a communicating system with its own Ion wall control, and QuietComfort.

What we see fail, and how we confirm it

SymptomUsual suspectHow it gets confirmed
Outdoor unit hums, fan does not turnRun capacitor or fan motorCapacitance and amp readings
Outdoor unit silent, indoor fan runningContactor, low-voltage wiring, disconnectVoltage at each point in the circuit
Furnace inducer runs but nothing lightsPressure switch or igniterSwitch and resistance tests
Burners light, then go outFlame sensorFlame signal reading
Weak airflow at the registersFilter, blower or ductsStatic pressure across the system

Airflow and static pressure

Static pressure tells us how hard the blower has to push to move air through the filter, the coil and the ducts. A high reading means too much restriction: a clogged filter, a dirty coil, undersized returns or crushed ducts. Restriction shortens blower motor life, lets the indoor coil freeze in summer and trips the furnace’s limit switch in winter. On a straightforward Heil system, a high reading often explains a complaint better than any failed part, and it costs nothing in parts to find out.

Matched indoor and outdoor units

An air conditioner or heat pump is rated for efficiency as a pair with a specific indoor coil or air handler. When only the outdoor unit is replaced, the old coil may not match it in size or refrigerant, and the system can fall short of its rating or run poorly. The same goes for a new furnace under an old coil. A replacement estimate should say which pieces are changing and why, and ours does, in writing.

Warranty and records

Heil coverage depends on the line, the install date and registration. Keep the installation invoice, the registration confirmation and the model and serial numbers of the outdoor unit, the furnace or air handler and the coil, along with a note of which indoor and outdoor combination was installed, since the efficiency rating applies to that pair. We are independent and not affiliated with Heil or any other manufacturer; see our warranty page for how parts and labor coverage differ.

Repair or replace

Capacitors, contactors, igniters, flame sensors, pressure switches and motors are repairs, and on most Heil equipment they are standard parts. Replacement comes up when a compressor or heat exchanger fails on an older system, when the system still uses R-22, or when repairs keep coming back. Before replacing equipment because a room never gets comfortable, test the ducts: new equipment on leaky or undersized ducts carries the same problem forward. See duct repair, and central air installation when the ducts themselves need to be redone.

Local notes

Many Menlo Park homes are mid-century ranch houses and older bungalows with original or patched ductwork and patchy insulation, which is where a static pressure test earns its place. In Atherton, homes running two or more systems with long duct runs need each system measured on its own, since one can be fine while the other starves for air. In Portola Valley, dust and pollen settle on outdoor coils over the summer; a gentle hose rinse in spring, with the power off, helps a single-stage unit keep up on hot afternoons.

Questions homeowners ask

What is a static pressure test?

A measurement of how hard the blower has to push air through the filter, the coil and the ducts. A high reading points to restriction, which can freeze the coil in summer and trip the furnace's limit switch in winter.

Why does my Heil system freeze up in summer?

Ice on the indoor coil or the refrigerant lines usually points to restricted airflow or low refrigerant. We check the filter, the coil and the static pressure before adding any refrigerant.

Can I replace just my Heil outdoor unit?

Sometimes, but the outdoor unit is rated as a pair with a specific indoor coil. If the old coil does not match in size or refrigerant, it usually has to be replaced too.

Are you a Heil dealer?

No. We are an independent HVAC company, not affiliated with Heil or any other manufacturer, and we service Heil equipment whoever installed it.

Need heating or cooling help?

24/7 emergency service · Same-day service available · Free installation estimates · Diagnosis before recommendations

Call (650) 567-5385